S'abonner

Radiothérapie « flash » à très haut débit de dose : un moyen d’augmenter l’indice thérapeutique par minimisation des dommages aux tissus sains ? - 29/09/15

Doi : 10.1016/j.canrad.2015.04.006 
V. Favaudon a, , b, c, d, e , C. Fouillade a, b, c, d, e, M.-C. Vozenin f
a Institut Curie, centre universitaire, bâtiment 110, rue Henri-Becquerel, 91405 Orsay cedex, France 
b Inserm U612, centre universitaire, bât. 110, 91405 Orsay, France 
c Inserm U1021, centre universitaire, bât. 110, 91405 Orsay, France 
d CNRS UMR 3347, centre universitaire, bât. 110, 91405 Orsay, France 
e Université Paris-Sud, centre universitaire, 91405 Orsay, France 
f Laboratoire de radio-oncologie, centre hospitalier universitaire Vaudois, 1011 Lausanne, Suisse 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 2
Vidéos 0
Autres 0

Résumé

Objectifs de l’étude

Les techniques de radiothérapie conformationnelle impliquent souvent la ré-irradiation des volumes irradiés à quelques secondes ou minutes d’intervalle. Ce « microfractionnement » est susceptible d’altérer la réponse des tissus cibles au rayonnement. D’autre part, les techniques de pencil beam scanning (PBS) qui se développent en protonthérapie, mettent en œuvre des microfaisceaux dans lesquels le débit de dose peut atteindre 200Gy/s, soit 1000 fois plus qu’en radiothérapie classique. Les conséquences de ces nouvelles modalités d’administration de la dose sur l’efficacité antitumorale aussi bien que sur la réponse des tissus sains, n’avaient pas été investiguées sur des modèles animaux. Afin de combler cette lacune, nous avons développé une méthodologie (« flash ») permettant d’irradier des souris en un temps très court (inférieur à 500ms) à haut débit de dose (supérieur ou égal à 40Gy/s).

Matériel et méthodes

Nous avons exploré, dans ces conditions, le développement de la fibrose pulmonaire radio-induite après irradiation thoracique bilatérale.

Résultats

L’analyse des résultats montre que l’irradiation flash n’induit pas de fibrose pulmonaire aux doses où l’irradiation conventionnelle en produit 100 % et réduit de manière spectaculaire l’expression du TGF-bêta et le taux d’apoptose dans le tissu pulmonaire. En revanche, aucune perte d’efficacité antitumorale n’a été observée sur trois modèles tumoraux exogéniques ou syngénique implantés en xénogreffes ou greffe orthotopique et l’escalade de dose qu’autorise l’épargne des tissus sains permet dans certains cas d’atteindre une cure complète.

Conclusion

En définitive, l’irradiation flash permet d’accroître le différentiel tumeurs/tissus sains à l’avantage de ces derniers, suggérant un potentiel prometteur en radiothérapie anticancéreuse.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

Pencil beam scanning and filter free techniques may involve dose-rates considerably higher than those used in conventional external-beam radiotherapy. Our purpose was to investigate normal tissue and tumour responses in vivo to short pulses of radiation.

Material and methods

C57BL/6J mice were exposed to bilateral thorax irradiation using pulsed (at least 40Gy/s, flash) or conventional dose-rate irradiation (0.03Gy/s or less) in single dose. Immunohistochemical and histological methods were used to compare early radio-induced apoptosis and the development of lung fibrosis in the two situations. The response of two human (HBCx-12A, HEp-2) tumour xenografts in nude mice and one syngeneic, orthotopic lung carcinoma in C57BL/6J mice (TC-1 Luc+), was monitored in both radiation modes.

Results

A 17Gy conventional irradiation induced pulmonary fibrosis and activation of the TGF-beta cascade in 100% of the animals 24–36 weeks post-treatment, as expected, whereas no animal developed complications below 23Gy flash irradiation, and a 30Gy flash irradiation was required to induce the same extent of fibrosis as 17Gy conventional irradiation. Cutaneous lesions were also reduced in severity. Flash irradiation protected vascular and bronchial smooth muscle cells as well as epithelial cells of bronchi against acute apoptosis as shown by analysis of caspase-3 activation and TUNEL staining. In contrast, the antitumour effectiveness of flash irradiation was maintained and not different from that of conventional irradiation.

Conclusion

Flash irradiation shifted by a large factor the threshold dose required to initiate lung fibrosis without loss of the antitumour efficiency, suggesting that the method might be used to advantage to minimize the complications of radiotherapy.

Le texte complet de cet article est disponible en PDF.

Mots clés : Radiation, Haut débit de dose, Flash, Complication, Fibrose, Poumon, TGF, Apoptose, Tumeur, Souris

Keywords : Radiation, Ultra-high dose-rate, Flash, Complication, Fibrosis, Lung, TGF, Apoptosis, Tumour, Mouse


Plan


© 2015  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 6-7

P. 526-531 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Hadronthérapie : quelle place et quelles perspectives en 2015 ?
  • L. Feuvret, V. Calugaru, R. Ferrand
| Article suivant Article suivant
  • Définition et applications cliniques des radiomics
  • C. Bourgier, J. Colinge, N. Aillères, P. Fenoglietto, M. Brengues, A. Pèlegrin, D. Azria

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.